FURI=NOT_SET, SDI=NOT_SET, FORI=NOT_SET, SCCI=NOT_SET, WCI=NOT_SET
Module Status
WCI | Window Compare Interrupt. 0 (NOT_SET): Read: A window compare interrupt has not occurred. Write: Clear the interrupt. 1 (SET): Read: A window compare interrupt occurred. Write: Force a window compare interrupt. |
SCCI | Single Conversion Complete Interrupt. 0 (NOT_SET): Read: A single data conversion interrupt has not occurred. Write: Clear the interrupt. 1 (SET): Read: A single data conversion interrupt occurred. Write: Force a single data conversion interrupt. |
SDI | Scan Done Interrupt. 0 (NOT_SET): Read: A scan done interrupt has not occurred. Write: Clear the interrupt. 1 (SET): Read: A scan done interrupt occurred. Write: Force a scan done interrupt. |
FORI | FIFO Overrun Interrupt. 0 (NOT_SET): Read: A data FIFO overrun interrupt has not occurred. Write: Clear the interrupt. 1 (SET): Read: A data FIFO overrun interrupt occurred. Write: Force a data FIFO overrun interrupt. |
FURI | FIFO Underrun Interrupt. 0 (NOT_SET): Read: A data FIFO underrun interrupt has not occurred. Write: Clear the interrupt. 1 (SET): Read: A data FIFO underrun interrupt occurred. Write: Force a data FIFO underrun interrupt. |